LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> AJ71QLP21
MITSUBISHI AJ71QLP21 Manual AJ71QLP21 Hardware User's Manual
Product model: AJ71QLP21
Name: MELSECNET/10 network module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 AJ71QLP21 User's Manual. 5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AJ71QLP21
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ71QLP21 User's Manual. ME-NET interface unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure AJ71QLP21 User's Manual. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc.. Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Input voltage range: AC100-120V/AC200-240V.
Output voltage: DC24V.
Output current: 1.2A additional power supply unit.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accorrding to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AJ71QLP21 Manual .
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% AJ71QLP21 Manual .
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
GI fiber optic cable module
AJ71LP21G
MITSUBISHI GI fiber optic cable module AJ71LP21G
G1-50/125 fier optic cale. Doule loop
MITSUBISHI
Coaxial cable module
AJ71LR21
MITSUBISHI Coaxial cable module AJ71LR21
3C-2V/5C-2V coaxial cale. Doule loop.
MITSUBISHI
Network module
AJ71AR21
MITSUBISHI Network module AJ71AR21
3C-2V/5C-2V coaxial cale. Doule circui
MITSUBISHI
SI/QSI fiber optic cable module
AJ71LP21
MITSUBISHI SI/QSI fiber optic cable module AJ71LP21
SI/QSI/H-PCF/ wide range H-PCF fier opt