Total input and output points: 8 points.
Input points: 8 points.
Output type: DC24V.
FX2N extension module.
The expansion module is an input and output expansion device of the power supply from the basic unit or the expansion unit,
Can choose the relay or crystal output models, to 8 points for the unit to connect MITSUBISHI PLC USER'S MANUAL.
Can be extended to FX3GA/FX3G, FX3GE, FX3GC, as well as FX3U, FX3UC series,
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-1PS-5V
FX3UC-16MT/D-P4
The number of connection points depends on the basic unit and the expansion unit. Can monitor and change the value of the soft component. Can also be simple to operate, change the data.
Can display Japanese and english.
Can be installed directly to the PLC, no wiring MITSUBISHI PLC USER'S MANUAL.
In addition, the use of FX3U-7DM-HLD, can be directly installed on the electrical cabinets. Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (sink).
Power consumption: 8W.
Weight (kg):0.2.
Size (WxHxD) mm:35x90x87.
Taking into account space saving and processing speed MITSUBISHI PLC USER'S MANUAL.
Connector input and output type compact high performance universal machine.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module FX3UC-16MT/D-P4 USER'S MANUAL.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory FX3UC-16MT/D-P4 USER'S MANUAL.
By installing the memory card box, the maximum can be extended to the 16000 step.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet. Power: 3 FX3UC-16MT/D-P4 USER'S MANUAL. 7kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling FX3UC-16MT/D-P4 Manual.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor MITSUBISHI PLC USER'S MANUAL.
The installation of thermal relay, to avoid overheating and burn the braking resistor.