Special module for RS-232C communication.
This serial communication module, you can communicate with the computer, printer, code reader and other equipment with RS-232C communication function.
The data can be transmitted through the buffer storage area of the module, and the data transfer between the PLC host and the module is realized.
When you connect to FX3UC, you need FX2NC-CNV-IF or FX3UC-1PS-5V.
Input and output points: 48 points.
AC power supply: AC100~240V.
Input points: 24 points.
Output points: 24 points.
Output form: transistor output (source).
Weight: 0.85kg.
Input signal voltage: DC24V.
FX2N series expansion unit
Expansion unit is an input and output expansion device with a built-in power supply MITSUBISHI FX2N-232IF.
As with the basic unit, the extension unit can be connected to a variety of input and output and special extension equipment
FX2N-232IF
Can connect to FX3GA/FX3G, FX3GE and FX3U.
AC power model, the built-in maximum DC24V 250mA/460mA supply power.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms MITSUBISHI FX2N-232IF.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with external serial devices MITSUBISHI FX2N-232IF. Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard MITSUBISHI RS-232C communication module.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time MITSUBISHI RS-232C communication module.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation MITSUBISHI RS-232C communicatioon module FX2N-232IF.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, usingg a eight digit password to protect your program MITSUBISHI FX2N-232IF. Length: 3 meters.
Specification: cable. Input expansion board (DC24V 4)
(FX1S and FX1N host general).