FR-A842-09620-2-60 Manual MITSUBISHI INVERTER FR-A842-09620-2-60 PLC FUNCTION Programming Manual
Product model: FR-A842-09620-2-60
Name: INVERTER
Brand: MITSUBISHI
Sort: PLC FUNCTION Programming Manual
File language: English
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Needle number: 40.
Specification: loose wire connector, 5 sets (0.3mm 2). Function expansion board for RS-485 communication.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI INVERTER Programming Manual. MITSUBISHI inverter series: FR-F840 FR-A842-09620-2-60
Voltage level: three phase 400V.
Power: 160kw.
SLD converter rated current: 361A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup MITSUBISHI INVERTER Programming Manual.
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor MITSUBISHI INVERTER Programming Manual.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor) FR-A842-09620-2-60 Programming Manual.
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FR-A842-09620-2-60 Programming Manual. Power supply: 120mA DC5V (PLC internal power supply), 160mA DC24V.
Analog output points: 4 points.
Voltage output: DC-10~10V.
Current output: DC0~20mA, 4~20mA.
Weight: 0.2kg.
Dimensions: 55 x 90 x 87.
The resolution of the 4 channel is 15bit binary + symbol 1bit (voltage),
High precision analog output module of 15bit binary (current) FR-A842-09620-2-60 Programming Manual.
Each channel voltage output (DC-10~10V) or current output (DC0~20mA, DC4~20mA) can be specified,
Mixed use.
With the form of the output and the upper and lower values and other rich features.
FX3UC-4AD can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Max input / output points: 128 points.
Supply voltage: 100 - 240VAC.
Input points: 64 points.
Output points: 64 points.
Output type: Transistor (source).
Power consumption: 65W.
Weight (kg):1.80.
Size (WxHxD) mm:350x90x86.
Built in CPU, power supply, input and output. By using a rich variety of functional extension boards and special adapters,
Can achieve high precision control.
Based on the function of FX2N has been greatly strengthened and enhanced.
High speed operation.
Basic instructions: 0.065 s/ instruction.
Application instruction: 0.642 s/ instruction.
Large capacity memory.
Built in program memory 64000 steps.
Flash memory cartridge with program transfer function.
Authentication。
Corresponding EN and UL/cUL authentication.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system.
Third generation high function micro programmable conntroller FR-A842-09620-2-60 Manual .
High speed, high efficiency, high performance, large capacity, and new features.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 poinnts MITSUBISHI INVERTER Programming Manual.
Auxiliary relay: 7680 points.
Timer: 512 points.
Counter: 235.
Data register: 8000.
Extended register: 32768 point.
Extended file register: 32768.