Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: relay.
Power consumption: 6W.
Weight (kg):0.25.
Size (WxHxD) mm:35x90x89.
Taking into account space saving and processing speed.
Connector input and output type compact high performance universal machine MITSUBISHI INVERTER Programming Manual.
Compact, scalable input / output
FR-A842-08660-2-60
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step MITSUBISHI INVERTER Programming Manual.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet. Master station module for CC-Link/LT.
I/O control can be used in the province of CC-LINK/LT.
Is to make PLC CC-LINK/LT as the main station of the FX system module.
The master station module and the remote I/O module can be connected by a special connector, and achieve the purpose of the distribution of the province MITSUBISHI INVERTER Programming Manual.
Up to 64 remote I/O station modules can be connected.
Remote I/O module is assigned a common X, Y soft components,
By using the same procedure as the common input and output FR-A842-08660-2-60 Programming Manual.
Even if the use of 2 points, 4 points of the remote I/O module, the number of soft components can be continuously assigned,
So it can be efficiently allocated I/O FR-A842-08660-2-60 Programming Manual. Connecting cable for handheld RH GOT and PLC.
Cable length: 6 meters.
Application: RS-422 connection and RS-232C connection. Axis of control: 1.
Instruction speed: 1Hz~1MHz FR-A842-08660-2-60 Programming Manual.
Applicable PLC:FX1N, FX2N, FX3U, FX2NC (to FX2NC-CNV-IF).
Applicable PLC:FX3UC (to FX2NC-CNV-IF or FX3UC-1PS-5V).
The maximum 1MHz high speed pulse, can carry on the high speed, high precision positioning.
Can be in the range oof 1Hz to 1Hz~1MHz as the interval output pulse FR-A842-08660-2-60 Manual .
The high speed moving time can be shortened to 1ms by using a dedicated start input.
Enhanced speed control function.
Support the approximate S type of accelerattion and deceleration function, form operation function, through the maximum 30kHz of the external input pulse rate of synchronization operation, etc MITSUBISHI INVERTER Programming Manual. .