LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E3S-R1E42
E3S-R1E42 INSTRUCTION sheet OMRON E3S-R1E42 Manual
Product model: E3S-R1E42
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Fitting materials: Iron, zinc plating.
Count: 1.
Accessories: Description, Phillips screws M4 × 25,
(with spring and plain washers) Nuts M4 ;
Material, Iron, zinc plating; Count, 2 .
Applicable sensor (mounting pitch on sensor side): E3JK.
Page: Dimensions, 5.
Control output: linear current output OMRON E3S-R1E42 Manual.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: - E3S-R1E42
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON E3S-R1E42 Manual.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) OMRON E3S-R1E42 Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Size: 96 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E3S-R1E42 INSTRUCTION sheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E3S-R1E42 INSTRUCTION sheet.
A new type of proportional control allows you to control the valve.
Related products
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AD91
OMRON Built-in Amplifier Photoelectric Sensor E3S-AD91
Sensing method: Diffuse-reflective Senso
OMRON
Transparent Object Detection Sensor
E3S-R17
OMRON Transparent Object Detection Sensor E3S-R17
Sensing method: Retro reflective. Appea
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AR31
OMRON Built-in Amplifier Photoelectric Sensor E3S-AR31
Sensing method: Retro-reflective Sensors