LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E3S-CR16
E3S-CR16 INSTRUCTION sheet OMRON E3S-CR16 Manual
Product model: E3S-CR16
Name: photoelectric switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E3S-CR16 Manual.
Ideal for the thermal input devices of Temperature Controllers E3S-CR16
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensing method: Retro-reflective (without MSR function).
Connection method: Pre-wired (2 m).
Sensing distance: 500 mm (80 mm).
Model: NPN output OMRON E3S-CR16 Manual.
Reliable Detection of Transparent,
Objects, Including Thin-walled Clear,
Plastic Bottles.
Uses OMRON''s unique optical system ("Inner View") that can,
detect various shapes of clear, plastic bottles.
Detects a wide range of bottles from 500-ml bottles to 2-l bottles,
and from single bottles to sets of stocked bottles.
Provides a high degree of protection (IP67), mutual interference,
prevention, and EN standard compliance OMRON E3S-CR16 Manual. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: E5AZ-R3 + E53-AZM + E53-AZH.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3S-CR16 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E3S-CR16 INSTRUCTION sheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Amplifier built-in type photoelectric switch
E3S-BT81
OMRON Amplifier built-in type photoelectric switch E3S-BT81
Small, easy to use. Detection mode: on t
OMRON
Built-in Amplifier Photoelectric Sensor
E3S-AR86
OMRON Built-in Amplifier Photoelectric Sensor E3S-AR86
Sensing method: Retro-reflective Sensors
OMRON
Transparent Object Detection Sensor
E3S-R67
OMRON Transparent Object Detection Sensor E3S-R67
Sensing method: Retro reflective. Appea