SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Controller network (control station / common station) / remote I/O network (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q2ASCPU User's Manual
Q2ASCPU
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q2ASCPU User's Manual.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network Q2ASCPU User's Manual.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data update is improved.
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened MITSUBISHI Q2ASCPU Manual .
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish the network can handle large capacity data MITSUBISHI Q2ASCPU Manual .
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station.8 channel.
Input: DC-10~10mA; 0~20mA.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000.
Conversion speed: 10ms/ channel MITSUBISHI Q2ASCPU Manual .
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have beeen greatly reduced due to the need for an external isolation amplifier Q2ASCPU Hardware.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee Q2ASCPU User's Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.