Item: Extension Terminal Set (For ZR-RX45).
with Internal 4 GB Flash Memory.
Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2.1 m3/min.
Maximum static pressure: 50 Hz, 47 Pa; 60 Hz, 44 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 46 dB OMRON ZR-XRT1.
Weight: Approx. 2220 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
ZR-XRT1
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment OMRON ZR-XRT1.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 36 V VDC.
Output current: 9.7 A.
Built-in fan: Yes OMRON ZR-XRT1.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage OMRON Data Logger.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life OMRON Data Logger. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models) OMRON Data Logger.
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages foor three-phase,
3-wire or 4-wire power supplies ZR-XRT1.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undeervoltages OMRON ZR-XRT1.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.