Cable length L: A, 5.0 m; B, 4.75 m.
Controllers with one touch.
Name: Finger Guard.
Datasheet available: Refer to page 25.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON XW2Z-500H-2G.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series
XW2Z-500H-2G
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Power ratings: 120 W OMRON XW2Z-500H-2G.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 5 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that OMRON XW2Z-500H-2G.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards OMRON Connecting Cables for Connector-Terminal Block Conversion Units. ) Cable length L: A, 20 OMRON Connecting Cables for Connector-Terminal Block Conversion Units. 0 m; B, 19.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Protect motors and other equipment from unstable,
voltages in the power supply system.
Protect motors and other equipment by detecting,
overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase power supplies OMRON Connecting Cables for Connector-Terminal Block Conversion Units.
Phase loss detection while the motor is operating.
Global power supply support. (Changed with a switch.).
Greater resistance to inverter noise.
Width of 177 XW2Z-500H-2G. 5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed ffor easy shipping to North America OMRON XW2Z-500H-2G.
Certification is pending for LR standards.
Models added with transistor outputs for superior contact reliability.