Type: Reverse wiring.
Cable length L: 0.5 m.
Controllers with one touch.
Power ratings: 30 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 1.3 A.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for OMRON XW2Z-050B-R1.
Easy System Commissioning.
New 90-W models with indication monitor that
XW2Z-050B-R1
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON XW2Z-050B-R1.
(Not compliant with EC Directives and other safety standards.) Pitch: 19.7 mm.
Applicable models: PYF08S.
Insulation color: Red.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available OMRON XW2Z-050B-R1. Type: Used for connecting Ionizers.
Cable length: 1,110 mm.
The highest level of ionization in its class.
Sensing and variable-AC system provides fast and meticulous ionization.
Linked Ionizers cover a wide area without causing uneven ionization.
Digital ion display provides simple and reliable settings. Control power supply voltage: 200/220 VAC OMRON Connecting Cables for Connector-Terminal Block Conversion Units.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring OMRON Connecting Cables for Connector-Terminal Block Conversion Units.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter OMRON Connecting Cables for Connector-Terminal Block Conversion Units.
Avaiilable in 7 supply voltage configurations XW2Z-050B-R1.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection OMRON XW2Z-050B-R1.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).