XS5H-D422-G80-F OMRON XS5H-D422-G80-F Round Water-resistant Connectors
Brand: OMRON
Name: Round Water-resistant Connectors
Model: XS5H-D422-G80-F
Cable specifications: Fire-retardant, Robot cable.
Cable length L: 5 m.
Cable outer diameter: 6 mm.
Angled Connectors.
Minimum order: 5.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.

Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*1).
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON XS5H-D422-G80-F.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that XS5H-D422-G80-F
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) OMRON XS5H-D422-G80-F.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON XS5H-D422-G80-F.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON Round Water-resistant Connectors.
Space-saving, integrated construction OMRON Round Water-resistant Connectors.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM OMRON Round Water-resistant Connectors. Power ratings: 120 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current: 5 A.
Boost Current: 6 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standardss:
UL508/60950-1, CSA C22 XS5H-D422-G80-F. 2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 4800-W models) OMRON XS5H-D422-G80-F.
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1.