Cable Specifications: Fire-retardant, Robot cable.
No. of connector poles: 4.
Cable connection direction: Straight.
No. of cable cores: 3.
Cable outer diameter: 6.0 mm dia.
Cable core cross-sectional area: 0.5 mm.
Cable length: 1 m.
DC: Model.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
94V-0 fire retardant rating.
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 1.1 m3/min; 60 Hz, 1.3 m3/min.
Maximum static pressure: 50 Hz, 67 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 48 dB OMRON XS2H-D421-CC0-F.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
XS2H-D421-CC0-F
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment OMRON XS2H-D421-CC0-F.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Type: single socket connector for PCB substrate.
Contact number: 6.
Wiring simple and e-CON * specifications for connectors;
Ideal choice for connecting sensors.
The connection of the spring clip which is verified by the industry is adopted OMRON XS2H-D421-CC0-F.
Wiring is simple, no special tools required,
Can be re wiring (maintenance).
Acceptable range for each connector
Stranded AWG28 (0.08mm2) ~ AWG20 (0.5mm2),
Any core wire size between.
(outer diameter: no more than 1.5mm).
A clamp capable of simultaneously connecting 4 lines when a connection is also provided OMRON Round Water-resistant Connectors.
UL standard (Document No. E103202) identified as a standard product OMRON Round Water-resistant Connectors.
Cable connector with the UL standard certification of products.
"Suitable cable dia: 3 mm dia. model (3 to 4 mm dia.).
Suitable core size: 0.18 to 0.3mm; 0.5 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Crimping.
DC: Model OMRON Round Water-resistant Connectors.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensuree a,
94V-0 fire retardant rating XS2H-D421-CC0-F.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on OMRON XS2H-D421-CC0-F.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.