I/O classification: Digital output.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: M3 terminal block.
Added to the Remote I/O Terminal Series.
I/O Points, or Output Points.
connecting to a single wire.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction.
Specifications: Outputs, NPN (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications. connector.
Rated I/O power supply voltage: 24 VDC.
Remote I/O Terminals with High.
Degree of Environmental Resistance.
(IP67) in Product Lineup Including OMRON SRT2-OD16T-1.
Economical Input, Output, and Mixed I/O Models.
Common Smart Slave functionality provides strong support for equipment,
operation status monitoring and effective maintenance
SRT2-OD16T-1
High degree of environmental resistance with dust-proof and drip-proof,
construction. (IP67)
Models with one connector for two outputs are available to make easier,
connection with hydraulic valve devices OMRON SRT2-OD16T-1.
(Models with 16 outputs and models with 16 mixed I/O)Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 inputs PNP.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON SRT2-OD16T-1.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs;
PNP (- common); 32 points.
I/O connections: MIL connector OMRON Transistor Remote I/O Terminals with 3-tier Terminal Block.
Rated internal circuit power supply voltage:
Supplied from the communications connector OMRON Transistor Remote I/O Terminals with 3-tier Terminal Block.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H). Specifications: Relay output; 16 points OMRON Transistor Remote I/O Terminals with 3-tier Terminal Blockk SRT2-OD16T-1.
I/O connections: M3 terminal block.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
I/O power supply voltage: Supplied from,
communications connector.
A Smart Slave with Relay Ouutputs and One-step,
Relay Replacement for Remote Maintenance OMRON SRT2-OD16T-1.
Capable of handling large-capacity output,
devices (3 A max.) Easy relay replacement.