Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 12V.
Output current: 12.5A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Detected voltage: DC.
Compact, Economical Plug-in Type Voltage.
Sensing Relay.
DPDT output contacts expand the application of the Sensor to,
wide-ranging fields including control, alarms, and indication.
Voltage control is possible in the same easy manner as electro,
magnetic relays, as the output relay of the sensor can be driven,
directly with a detection signal OMRON S8VM-15012CD.
Wide voltage setting range with fine setting capability
S8VM-15012CD Square socket.
Equipped with a wide variety of square and round sockets,
Surface connection and back connection.
With a finger touch protection type.
With the fixed bracket, PYF cross tab.
Add no screw series. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan) OMRON S8VM-15012CD.
Capacity: 100W.
Output voltage: 5V.
Output current: 20A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity OMRON S8VM-15012CD.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage OMRON Switching Mode Power Supply.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation OMRON Switching Mode Power Supply.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)"Rated voltage: 100 V OMRON Switching Mode Power Supply.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2,700 r/min; 60 Hz, 3,100 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1.5 m3/min.
Maximum static pressure: 50 Hz, 91 Pa; 60 Hz, 85 Pa.
Noise: 50 Hz, 49 dB; 60 Hz, 52 dB.
Weight: Approx. 1,120 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work S8VM-15012CD.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and VVent Attachment OMRON S8VM-15012CD.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades.