LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
RX41C4 Extended SRAM card MITSUBISHI RX41C4 IQ-R MELSEC series consists of CPU module, power module, substrate module, input and output module, intelligent function module and so on 
Brand: MITSUBISHI
Name: Input module
Model: RX41C4
"Input points: 32 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 4.0mA.
Response time: 0.1 ~ 70ms.
Common way: 32 point / public end.
Interrupt function: have.
External wiring connection mode: 40 pin connector.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "

Analog input channel number: 4CH.
Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/W26Re.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range MITSUBISHI RX41C4 RX41C4
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection: 18 point screw terminal two.
Temperature tracking function can be monitored in real time MITSUBISHI RX41C4.
Using Works3 GX in the temperature function, can be real-time tracking temperature, in the confirmation of the temperature waveform and parameter adjustment.
In addition, the temperature can be saved as a CSV file after the export, the use of a variety of purposes.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control MITSUBISHI RX41C4. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
Temperature rising function between modules
By cooperating with the time of arrival of a number of loops, the average temperature is controlled MITSUBISHI Extended SRAM card.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion MITSUBISHI Extended SRAM card. Can be divided into 16 groups, with its heating up to the time,
Reduce the overall system in heating up the waste of energy. Analog input channel number: 4CH.
Available thermocouple: B, R, S, K, E, J, T, N, U, L, PL II, W5Re/W26Re.
Available temperature resistance: PT100, JPt100 MITSUBISHI Extended SRAM card.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: none.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Reduce the incidence of non qualified products by inhibiting the effect of external interference,
Improve the efficiency of life and product quality by using external interference suppression function,
Thee temperature fluctuation caused by external disturbance can be rapidly attenuated,
To ensure that the product processing within the specified temperature range, reduce the incidence of substandard products RX41C4.
This function is very eeffective for the product packaging machine and injection molding machine, the semiconductor manufacturing device of the wafer heating board and so on MITSUBISHI RX41C4.


...More relevant models >>>>
Last one: RX40C7
next one: RX42C4