LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
R87F-A3A13HP OMRON AC Axial Fans OMRON R87F-A3A13HP
Brand: OMRON
Name: AC Axial Fans
Model: R87F-A3A13HP
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.160 A; 60 Hz, 0.130 A .
Rated input: 50 Hz, 14 W ; 60 Hz, 12 W .
Rated rotational speed: 50 Hz, 2400 r/min; 60 Hz, 2800 r/min.
Maximum flow rate: 50 Hz, 1.9 m3/min; 60 Hz, 2.2 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 42.2 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 43 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics.

Input / output: 32.
Pole number: 40.
I/O: output.
Common mode terminal: YES.
Connector mounting type: XG4A-4031.
Cable connector type: XG4M-4030-T.
The use of non threaded terminals can greatly reduce the amount of plant wiring and the required hours.
The caliper terminal so that you can no longer without fastening screws OMRON R87F-A3A13HP.
Only insert the rod - shaped terminal to complete a touch type wiring R87F-A3A13HP Suitable cable dia: 3 mm dia. model (3 to 4 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Soldering.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON R87F-A3A13HP.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 OMRON R87F-A3A13HP. Shape: DIP straight terminal.
Pole number: 20.
Pole pole number: 1.
Minimum packing unit: 70.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization OMRON AC Axial Fans.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided OMRON AC Axial Fans.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked OMRON AC Axial Fans.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make thhe protection and coordination of digital DCR R87F-A3A13HP.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme OMRON R87F-A3A13HP.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.


...More relevant models >>>>
Last one: R87F-A1A13HP
next one: R87F-A4A13HP