LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
Q2ASHCPU MITSUBISHI CPU unit Q2ASHCPU
Brand: MITSUBISHI
Name: CPU unit
Model: Q2ASHCPU
Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment.

Available network: Profibus-DP.
Function: Master station.
The A1SJ71PB96F and A1SJ71PB92D modules allow a PLC ANS to connect to the Profibus system,
Meet the CE standard, using SWOIX/ProfiMap special programming software.
A1SJ71PB96F compatible with Profibus-FMS, as a master or client;
A1SJ71PB92D compatible with Profibus-DP, can be used as a master to control the remote Profibus-DP I/O MITSUBISHI Q2ASHCPU Q2ASHCPU 3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI Q2ASHCPU.
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI Q2ASHCPU.
So, sometimes also known as the order control MITSUBISHI CPU unit.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Temperature sensor: PT100, 3 wire system MITSUBISHI CPU unit.
The A1S62RD3 and A1S62RD4 temperature sensor input modules allow the platinum resistance temperature sensing element to be directly connected to the PLC,
This component converts a signal from a temperature measuring element to a numeric value that represents a temperature measurement value,
This temperature value can be used for the control process MITSUBISHI CPU unit.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC andd the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI Q2ASHCPU Q2ASHCPU.
This phenomenon is called the I/O delay time effect.


...More relevant models >>>>
Last one: Q2ASCPU-S1
next one: Q2ASHCPU-S1