Dust measurement type, 5 µm (10 µm), 20 µm (30 µm), 50 µm min.
Make your entire production environment visible.
Multi-point monitoring of environmental data and central control.
Product name: Split type CT, Connector: For connecting the branch cable,
Cable length: 0.2 m.
Power supply: Battery/DC cable.
Easy and Quick "Checking Power"at the Worksite. Item (Measured particle diameter): Air Particle Sensor,
Particle measurement type 0.3, 0.5, or 1.0 µm min.
Make your entire production environment visible OMRON ZN-PD50-SA.
Multi-point monitoring of environmental data and central control
ZN-PD50-SA Applicable circuits: Single-phase, 2-wire: 100 to 480 VAC;
Single-phase, 3-wire: 100/200 VAC; Three-phase, 3-wire: 100 to 480 VAC;
Three-phase, 4-wire: 85 to 277 VAC.
Power supply voltage (shared): 100 to 240 VAC.
Dimensions: 96 × 48 × 93 (H × W × D).
Communications: RS-485.
Protocol: CompoWay/F, 31 nodes; Modbus, 99 nodes,
(Both are supported by the same model OMRON ZN-PD50-SA. )
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function OMRON ZN-PD50-SA.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy OMRON Next-Generation Production Environment Sensors.
Automatic range switching for accurate measurement of standby and stopped power OMRON Next-Generation Production Environment Sensors.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications OMRON Next-Generation Production Environment Sensorrs ZN-PD50-SA.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Make your entire production environment visible.
Multi-point monitoring of environmental data and central control OMRON ZN-PD50-SA. Item: Sensor head 10 m type.
Easy temperature and humidity control with an SD Card.