Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
other devices.
Relay Box not Required.
mounting.
Easier Maintenance.
maintenance time.
Compact design (160 x 54 mm (W x H)) (8-point models).
the switch and connectors on the front side of the Terminal.
System Configuration.
Internal I/O common: NPN.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 120 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min OMRON SRT2-OD04CL-1. )
Easy wiring using industry standard,
e-CON connectors
SRT2-OD04CL-1
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software OMRON SRT2-OD04CL-1.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. Specifications: I/O, NPN (input: + common, output: - common), 16 inputs/16 outputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector OMRON SRT2-OD04CL-1.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws OMRON Waterproof Terminals. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection OMRON Waterproof Terminals.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON Waterproof Terminals.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error SRT2-OD04CL-1. Classification: Analog Output Terminal.
I/O points: 1 or 2 (selectable with DIP switch).
Compact Analog Output Model is thhe,
Same Shape as 16-point Remote I/O Terminals OMRON SRT2-OD04CL-1.
Two output points or 1 output point is selectable.
Resolution: 1/6,000.
105 x 48 x 50 (W x H x D).