The output signal can open collector output inverter host standard.
Can be from the voltage output terminal (AM0), the current output terminal (AM1) output analog signal (output frequency, output current, etc.).
Can be connected to the 20mA DC or 10V DC meter. "
Power: 110kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI FR-A8AY. ) MITSUBISHI inverter FR-D740 series
FR-A8AY
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI FR-A8AY.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft MITSUBISHI FR-A8AY. Power: 22kw.
Voltage: 400V.
The surge voltage of the motor can be suppressed when the 400V motor is driven by a frequency converter.
Motor suitable for 5 MITSUBISHI 3 phase 200V converter. 5 to 37kW. Purpose: to operate, monitor, and change the parameters through the network.
Applicable frequency converter: FR-A700, FR-F700, FR-E700 MITSUBISHI 3 phase 200V converter. MITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 0.4KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
The alternating current of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current IIm1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation MITSUBISHI 3 phase 200V converter MITSUBISHI FR-A8AY FR-A8AY.