MITSUBISHI A1SJ71E71-B2-S3 Ethernet interface module MITSUBISHI A1SJ71E71-B2-S3
Brand: MITSUBISHI
Name: Ethernet interface module
Model: A1SJ71E71-B2-S3
Available network: 10BASE2.
Max / total distance: 185/925m.
A1SJ71E71 is a compact Ethernet interface module,
Used to hang PLC series ANS to ethernet.
There are two kinds of hanging network modules: A1SJ71E71-B2-S3 and A1SJ71E71-B5-S3 respectively corresponding to 10BASE2 and 10BASE5,
So that the vast majority of installed cable can continue to use.

SI/QSI/H-PCF/ wide H-PCF optical cable double loop PC (control station / common station) / remote I/O network (remote master station). With external power supply function.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order MITSUBISHI A1SJ71E71-B2-S3 A1SJ71E71-B2-S3
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of MITSUBISHI A1SJ71E71-B2-S3.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on MITSUBISHI A1SJ71E71-B2-S3 MITSUBISHI Ethernet interface module.
This phenomenon is called the I/O delay time effect MITSUBISHI Ethernet interface module. I/O control method: refresh mode or direct mode.
User program storage capacity: 8K step.
I/O points: 256 points.
Memory capacity: bytes 64K.
ANSCPU has been updated to ANSHCPU, and it has the following advantages.
16 bit dedicated microprocessor.
Large capacity battery backup memory RAM.
Extended I/O control capability MITSUBISHI Ethernet interface module.
Dedicated CC-Link instruction.
Capacity for extended comment storage.
Write speed processing. 3 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 3 slot main substrate.
AnS series of modules can be installed. 4 channel analog input module.
A1S64AD analog input module can accept the voltage or current siggnal,
The built-in microprocessor converts these signals to binary values,
For the control program to enjoy A1SJ71E71-B2-S3.
Signal can be instantaneous read, can also be programmed time / frequency average,
The offset and gain value can be set, and this component also includes the following performance:
4 input channels MITSUBISHI A1SJ71E71-B2-S3.
High resolution digital output.
Total accuracy plus or minus 1%.