LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
LJ71E71-100-CM Temperature control module Transmission speed: 150Mbps MITSUBISHI LJ71E71-100-CM
Brand: MITSUBISHI
Name: Ethernet interface module
Model: LJ71E71-100-CM
Transmission speed: 100Mbps/10Mbps.
MELSOFT connection.
SLMP cross letter (MC protocol).
Communication protocol support function.
E-mail function.
Web function.
Collect / change CPU module data from the other side of the device.
SLMP (MC protocol) communication
SLMP is a protocol that uses Ethernet to access SLMP devices from the other device.
If it is possible to follow the SLMP control procedures to send and receive messages to the device,
The communication can be carried out by SLMP. MC can also support the previous agreement.
MELSOFT connection
Can be connected with the programming tool Works2 GX and other MELSOFT products.
In addition, through the use of communication tools to support the sale of (MX Component),
Regardless of the details of the protocol (how to send and receive procedures),
Can create a communication program on the upper side of the system.
It can easily connect to BACnet and MODBUS /TCP
Communication protocol support function
Through the Works2 GX communication protocol support function, can easily set the communication with the other equipment required for the agreement.

"Universal output function: source type.
Program capacity: 60K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
CPU built-in functions can be easily set through programming tools MITSUBISHI LJ71E71-100-CM.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool LJ71E71-100-CM
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " MITSUBISHI LJ71E71-100-CM.
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators MITSUBISHI LJ71E71-100-CM. "Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal MITSUBISHI Temperature control module.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI Temperature control module MITSUBISHI Temperature control module. Number of input channels: 4ch.
Input voltage: DC - 10 - 10V.
Input current: DC0 ~ 20mA.
Input voltage: 100 ~ 100mV / minute.
Input thermocouple: K, J, T, E, N, R, S, B, U, L, PL II, W5Re/W26Re.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50.
Conversion speed: 50ms/ch.
Resolution (voltage / current / micro voltage): 1/20000
Resolution (thermocouple): B, R, S, N, PL II, W5Re/W26Re:0.3,, K, E, J, T, U, L:0.1.
Temperature measuring resistance: Pt100, JPt100:0.03, /0.1, Pt1000, Pt50:0.1.
Reduce the programming time.
The digital output value can be easily converted (zoom) to any number of functions without the program.
No need to use ladder diagram conversion program, can reduce the programming time.
Zoom setting example (L60AD4-CM).
The digital output value (20000 ~ 0) of the input range 20mA ~ 4mA is scaled to the value of positive and negative 20000.
Digital filter function
Simply set the parameters, you can eliminate the function of tthe redundant frequency components LJ71E71-100-CM.
Can be selected from low pass filter, high pass filter, medium pass filter.
No need to filter the ladder, can reduce programming time.
In addition, the conversion value of the A/D convertted by the filter can be obtained at the same time,
Therefore, the total processing time from the conversion to the filter processing can be shortened MITSUBISHI LJ71E71-100-CM.


...More relevant models >>>>
Last one: LJ72MS15-CM
next one: LJ71C24-CM