Input power: DC24V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided.
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS).
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc..
Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal MITSUBISHI L63P-CM.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system
L63P-CM
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged MITSUBISHI L63P-CM.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability MITSUBISHI L63P-CM. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output MITSUBISHI A800 series to A900 series conversion line. Convert connector to screw relay terminal.
2 wire connection, no need to use common terminal MITSUBISHI A800 series to A900 series conversion line.
Negative common end use. Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Convert connector to screw relay terminal.
The action of the signal of the conversion module is shown in the light of the lamp MITSUBISHI A800 series to A900 series conversion line.
Negative common end with display. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space.
Management of abnormal information through the RAS function
An error occcurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network L63P-CM.
Even if the power of the system is cut off,, the error record in the locked area is still retained,