Name: Temperature Monitoring Relay
Model: K8AB-TH12S AC100-240
Size: K8AB-TH 22.5 × 90 × 100 mm.
Supply voltage: 100 to 240 VAC.
Type: Temperature input.
Number of outputs: 1 (relay).
Input type: Thermocouple.
Setting unit (setting range): Unit: 10°C/°F (See note 1.).
Compact and Slim Relay Ideal for.
Temperature Alarms and Monitoring.
Excessive temperature increases can be prevented and,
abnormal temperatures can be monitored.
Temperature monitoring in slim design with a width of just 22.5 mm.
Simple function settings using DIP switch.
Universal-input support for thermocouple or Pt100 sensor input.
Selectable output relay: Non-fail safe/fail safe.
Alarm status identification with LED indicator.

Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element OMRON K8AB-TH12S AC100-240.
Burnout Detector compatible with a,
wide-range of heater control methods K8AB-TH12S AC100-240
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance OMRON K8AB-TH12S AC100-240.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial OMRON K8AB-TH12S AC100-240.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed OMRON Temperature Monitoring Relay.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator OMRON Temperature Monitoring Relay.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Cable type: Standard Cables.
Type: M12 Panel-mounting PCB Straight Terminals.
Cable length: --.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC OMRON Temperature Monitoring Relay.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages and undervoltages for three-phasee,
3-wire or 4-wire power supplies K8AB-TH12S AC100-240.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire,
power supply.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and,
undeervoltages OMRON K8AB-TH12S AC100-240.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.


...More relevant models >>>>