K2CU-F20A-DGS OMRON Heater Element Burnout Detector K2CU-F20A-DGS
Brand: OMRON
Name: Heater Element Burnout Detector
Model: K2CU-F20A-DGS
Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.

Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for Monitoring 3-phase Power.
Supplies for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor overvoltages, undervoltages, phase sequence,
and phase loss for three-phase 3-wire or 4-wire power,
supplies with just one Unit OMRON K2CU-F20A-DGS.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply K2CU-F20A-DGS
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit (switchable).
Output status can be monitored using LED indicator. Category: incidental cover with under voltage detection function OMRON K2CU-F20A-DGS.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 24V.
Output current: 4.5A.
Alarm output: leakage type.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity OMRON K2CU-F20A-DGS.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage OMRON Heater Element Burnout Detector.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock OMRON Heater Element Burnout Detector.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2 OMRON Heater Element Burnout Detector. (except for type 15/30W)"Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operaation time,
is indicated from the start of operation K2CU-F20A-DGS.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions OMRON K2CU-F20A-DGS. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,


...More relevant models >>>>
Last one: K2CU-F20A-CGS
next one: K2CU-F20A-EGS