LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
K2CA-HC OMRON K2CA-HC Over current relay
Brand: OMRON
Name: Over current relay
Model: K2CA-HC
Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protection and coordination of digital DCR.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any time.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.

Output voltage: 12 V.
Output current: 2.5 A.
Screw terminal Model: With Bus Line (See note 1.).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels) OMRON K2CA-HC K2CA-HC
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models).
RoHS-compliant.
Input conditions: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable.)
Operating temperatures to –20°C (24-V models). Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage OMRON K2CA-HC.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.046 A; 60 Hz, 0.039 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2600 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 39.2 Pa; 60 Hz, 53.9 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive OMRON K2CA-HC.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON Over current relay.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA OMRON Over current relay.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage OMRON Over current relay.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.420 A; 60 Hz, 0.370 A .
Rated input: 50 Hz, 43 W; 60 Hz, 40 W.
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3250 r/min.
Maximum flow rate: 50 Hz, 5.0 m3/min; 60 Hz, 5.8 m3/min.
Maximum static pressure: 50 Hz, 118 Pa; 60 Hz, 88 Pa.
Noise: 50 Hz, 52 dB; 60 Hz, 56 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metaal-bladed models,
(28 type) included in series K2CA-HC.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product OMRON K2CA-HC. Check the information given for available models of Axial fans and,
the information in Characteristics.