Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT (for power switching).
Time ranges: 0.04 s to 3 h.
12, 24, 48, 125, 100 to 110 VDC.
Mounting: Surface mounting (with PCB terminals).
Miniature Timer Compatible with the MY Relay.
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting.
A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and CSA.
Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors OMRON H3Y-2-0
H3Y-2-0
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm. Type of input: AC current input OMRON H3Y-2-0.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display OMRON H3Y-2-0.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm OMRON Solid-state Timer. Operating modes: Flicker ON start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC OMRON Solid-state Timer.
0.05 s to 300 h models: 11-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible OMRON Solid-state Timer.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available. Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: relay contact; PASS1c; H, L: each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precisioon measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors H3Y-2-0.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measuremment and identification situations OMRON H3Y-2-0.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard applicable certification (