LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
G3F-203SLN-VD DC12 OMRON G3F-203SLN-VD DC12 Solid State Relays
Brand: OMRON
Name: Solid State Relays
Model: G3F-203SLN-VD DC12
Isolation: Phototriac coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 12 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix).

Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC/DC 48V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel OMRON G3F-203SLN-VD DC12.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals G3F-203SLN-VD DC12
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires OMRON G3F-203SLN-VD DC12.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection) OMRON G3F-203SLN-VD DC12.
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short OMRON Solid State Relays.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters OMRON Solid State Relays.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable) OMRON Solid State Relays.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Mounting type: W-bracket(see note).
Contact form: DPST-NO/DPST-NC.
Quick-connect terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power for motorr loads,
as well as resistive and inductive loads G3F-203SLN-VD DC12.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and betweenn the coil and contacts OMRON G3F-203SLN-VD DC12.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA.


...More relevant models >>>>
Last one: G3F-203SLN DC12