LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
FX2NC-32MT-D/UL MITSUBISHI FX2NC-32MT-D/UL Power supply voltage: 24VDC 
Brand: MITSUBISHI
Name: PLC
Model: FX2NC-32MT-D/UL
Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (sink).
Power consumption: 8W.
Weight (kg):0.2.
Size (WxHxD) mm:35x90x87.
Taking into account space saving and processing speed.
Connector input and output type compact high performance universal machine.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet.

Analog input points: 4 points (PT1000/Nil000).
Resolution: 0.1 degrees.
Weight: 0.1kg.
Dimensions: 17.6 x 90 x 89.5.
FX3U-4AD-PNK-ADP is a PT1000/Nil000 temperature sensor with analog input adapter.
Thermocouple (K type, J type) and PT1000/Nil000 temperature sensor with analog input adapter.
-100~1000 degree can be measured by 4 channels MITSUBISHI FX2NC-32MT-D/UL.
No programming to send data to FX3 series FX2NC-32MT-D/UL
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U,
Need to convert adapter or function extension board. Total input and output points: 40 points.
Input points: 24 points.
Output points: 16 points.
Output type: transistor output.
Power supply voltage: AC100-240V.
Input signal voltage: DC24V.
8K capacity of the RAM memory, the maximum can be extended to 16K MITSUBISHI FX2NC-32MT-D/UL.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI FX2NC-32MT-D/UL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard MITSUBISHI PLC.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017) MITSUBISHI PLC.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate MITSUBISHI PLC.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program. Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: relay.
Power consumption: 25W.
Weight (kg):0.65.
Size (WxHxD) mm:150x90x87.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N serries can be connected to the input and output expansion modules and special function modules FX2NC-32MT-D/UL.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI FX2NC-32MT-D/UL.