LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
FR-F840-00083-2-60 MITSUBISHI IP55 converter built-in DC reactor MITSUBISHI FR-F840-00083-2-60
Brand: MITSUBISHI
Name: Three phase 400V grade frequency converter
Model: FR-F840-00083-2-60
MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 3.7kw.
SLD converter rated current: 8.3A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control.

Power: 30kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor MITSUBISHI FR-F840-00083-2-60. (the IP55 series has a built-in DC reactor FR-F840-00083-2-60)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 1.5KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus MITSUBISHI FR-F840-00083-2-60.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure MITSUBISHI FR-F840-00083-2-60.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements MITSUBISHI IP55 converter built-in DC reactor. Power: 280kw.
Voltage: 200V.
Sine wave filter.
The voltage and current of the motor can be adjusted to a sine wave MITSUBISHI IP55 converter built-in DC reactor.
The sine wave filter is installed to the output terminal of the inverter.
Applicable to FR-A820-03800 (75K) above and FR-A840-02160 (75K) and above frequency converter.
Sine wave filter is equivalent to the operational characteristics of the sine wave power driver, can provide the following benefits MITSUBISHI IP55 converter built-in DC reactor.
Low noise.
No surge current.
Reduce motor loss (standard motor). Power: 3.7kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-033800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FR-F840-00083-2-60.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motorr power used to select the DC reactor MITSUBISHI FR-F840-00083-2-60.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.)


...More relevant models >>>>