FR-F740P-90K-CHT Three phase 400V level inverter MITSUBISHI FR-F740P-90K-CHT
Brand: MITSUBISHI
Name: 3 phase 400V converter
Model: FR-F740P-90K-CHT
"MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 90KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter. "

MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 18.5KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions MITSUBISHI FR-F740P-90K-CHT.
High level driving performance.
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operated at high precision in the super low speed region without the need of the encoder FR-F740P-90K-CHT
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc MITSUBISHI FR-F740P-90K-CHT. ) and torque control. Power: 22kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor MITSUBISHI FR-F740P-90K-CHT.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling MITSUBISHI Three phase 400V level inverter.
MYS type resistor can be used. But please pay attention to the allowable brake use rate MITSUBISHI Three phase 400V level inverter.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor.
The installation of thermal relay, to avoid overheating and burn the braking resistor. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 11.0kw.
SLD converter rated current: 31 MITSUBISHI Three phase 400V level inverter. 0A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverrter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FR-F740P-90K-CHT.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out MITSUBISHI FR-F740P-90K-CHT.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "