FR-BU2-H15K DC reactor Voltage: 400V MITSUBISHI FR-BU2-H15K
Brand: MITSUBISHI
Name: Brake unit
Model: FR-BU2-H15K
Power: 15kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available.
Please select according to the required braking torque.

Superior high efficiency IPM motor.
Output power: 0.75kw.
Rated speed: 1500r/min.
Voltage level: 200V.
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time MITSUBISHI FR-BU2-H15K. Power: 37kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current FR-BU2-H15K
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V MITSUBISHI FR-BU2-H15K.
Frequency converter capacity: 355KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor MITSUBISHI FR-BU2-H15K MITSUBISHI DC reactor.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity MITSUBISHI DC reactor. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 15KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions MITSUBISHI DC reactor.
High level driving performance.
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operatted at high precision in the super low speed region without the need of the encoder FR-BU2-H15K.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequuency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc MITSUBISHI FR-BU2-H15K. ) and torque control.