The operation, monitoring, parameter modification and other operations can be carried out by computer or PLC.
MITSUBISHI inverter FR-A720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 1.5KW.
Inverter output for the PWM wave, containing more harmonic.
Frequency conversion power sensor through the input voltage and current signals to exchange sampling,
Sampling value through cable, optical fiber and other transmission systems and digital input frequency conversion power analyzer,
The sampling value of the voltage and current is calculated by the digital input frequency conversion power analyzer,
It can obtain the parameters such as voltage effective value, current effective value, fundamental wave voltage, fundamental current, harmonic voltage, harmonic current, active power, fundamental wave power and harmonic power MITSUBISHI FR-A8NP MITSUBISHI FR-A8NP
FR-A8NP MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 22KW.
Frequency converter common frequency of a given way: the operator keyboard is given, the contact signal given, analog signal given, the pulse signal given and communication methods given, etc..
These frequencies have their advantages and disadvantages, and should be selected according to the actual needs MITSUBISHI FR-A8NP.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions MITSUBISHI 3 phase 400V converter MITSUBISHI 3 phase 400V converter. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 11KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) MITSUBISHI 3 phase 400V converter.
Starting with power frequency power supply, the starting current is 6~7 times of thee rated current, therefore, the impact on the mechanical and electrical FR-A8NP.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load MITSUBISHI FR-A8NP.