FR-A820-15K-1(FR-A820-00770-2-60) Structure and function: Standard model MITSUBISHI FR-A820-15K-1(FR-A820-00770-2-60) IP55 converter built-in DC reactor
Brand: MITSUBISHI
Name: Three phase 200V grade frequency converter
Model: FR-A820-15K-1(FR-A820-00770-2-60)
MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 15kw.
SLD converter rated current: 77A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.

MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 450kw.
SLD converter rated current: 962A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON MITSUBISHI FR-A820-15K-1(FR-A820-00770-2-60) FR-A820-15K-1(FR-A820-00770-2-60)
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation MITSUBISHI FR-A820-15K-1(FR-A820-00770-2-60).
Can reduce the power consumption in the stop. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 7.5kw.
SLD converter rated current: 49A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models MITSUBISHI FR-A820-15K-1(FR-A820-00770-2-60).
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station MITSUBISHI IP55 converter built-in DC reactor.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine MITSUBISHI IP55 converter built-in DC reactor.
No external PID controller is used to control the external machine, so the system cost can be reduced. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16 MITSUBISHI IP55 converter built-in DC reactor. 7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, bbut also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station FR-A820-15K-1(FR-A820-00770-2-60).
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same timme, used in the control of the external machine MITSUBISHI FR-A820-15K-1(FR-A820-00770-2-60).
No external PID controller is used to control the external machine, so the system cost can be reduced.


...More relevant models >>>>