Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Control axis: maximum 16 axes.
Operation cycle: 0.88ms, 1.77ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 16 set MITSUBISHI FA-TH16YRAC20S.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control
FA-TH16YRAC20S
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program.
Let motion control more simple MITSUBISHI FA-TH16YRAC20S. The terminal row is converted to e-CON.Number of input channels: 8ch.
Input temperature resistance: Pt1000, Pt100, JPt100, Pt50, Ni500, Ni120, Ni100, Cu100, Cu50.
Conversion speed: 40ms/ch.
Resolution: 0.1.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm MITSUBISHI FA-TH16YRAC20S.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement MITSUBISHI Conversion module MITSUBISHI Conversion module.
High speed, smooth continuous analog output.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulated according to the set conversion period MITSUBISHI Conversion module.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output. Enter points: 64 points.
Rated input voltage: DC24V.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: 64 points).
External wiring connection: 40 pin connector two.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an imporrtant part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on MITSUBISHI FA-TH16YRAC20S FA-TH16YRAC20S.