Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Resistance thermometer input, E5GN-R1P.
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
clamp terminal blocks.
manual, RUN/STOP, and alarms) and the PV or SV.
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: -- OMRON E5GN-R1TD-C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --
E5GN-R1TD-C
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 OMRON E5GN-R1TD-C. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON E5GN-R1TD-C.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Control output 1: Voltage output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485 OMRON Basic-type Digital Temperature Controller.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read OMRON Basic-type Digital Temperature Controller.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm OMRON Basic-type Digital Temperature Controller.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. The application of protective tube diameter: diameter of 10mm.
A varriety of high precision temperature sensor series E5GN-R1TD-C.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours.
A temperature sensor is used as a thermal sensor for a theermostat OMRON E5GN-R1TD-C.
According to the temperature, place, the surrounding environment to be measured.
Products with various shapes, shapes, lengths and terminals.