Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Protective tubing length L: 20cm.
Protective tubing diameter: D = 6.4.
L2: 150 mm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON E5CN-C2PBT.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E5CN-C2PBT Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Auxiliary outputs: 2.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature OMRON E5CN-C2PBT.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV OMRON E5CN-C2PBT.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Terminal type: Exposed-lead Models OMRON Foundation type temperature controller.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard OMRON Foundation type temperature controller.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON Foundation type temperature controller. Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increaseed,
Further performance improvement E5CN-C2PBT.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV OMRON E5CN-C2PBT.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.