Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 OMRON E5AN-QY3BT-N.
Event input: 2 points.
Remote SP input: -.
Transfer output: -
E5AN-QY3BT-N
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications OMRON E5AN-QY3BT-N.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication OMRON E5AN-QY3BT-N.
Combined temperature control device through component communication. Control output 1: Voltage output.
Control output 2: --.
Auxiliary output: Three.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read OMRON Foundation type temperature controller.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance OMRON Foundation type temperature controller.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other OMRON Foundation type temperature controller.
Size: E5CSV 48 × 48mm.
Type: Terminal block.
Control modes: ON/OFF or PID.
Alarms: 2 (See note.).
Outputs: Voltage (for driving SSR).
Easy Setting Using DIP Switch and Simple.
Functions in DIN 48 × 48 mmm-size Temperature E5AN-QY3BT-N.
Controllers.
Easy setting using DIP switch.
Models with two alarms added to Series, ideal for temperature,
alarm applications.
Universal-input (thermocouple/platinum resistance thermometer),
models also aavailable OMRON E5AN-QY3BT-N.
Clearly visible digital display with character height of 13.5 mm.
Models available with black in addition to white cases.