Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input OMRON E5AN-HTPRR202B-FLK.
Heating wire break, SSR fault detection function: 1 points
E5AN-HTPRR202B-FLK
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm OMRON E5AN-HTPRR202B-FLK.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON E5AN-HTPRR202B-FLK.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication OMRON Programmed temperature controller.
A new type of proportional control allows you to control the valve OMRON Programmed temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON Programmed temperature controller.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%)),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs E5AN-HTPRR202B-FLK.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV OMRON E5AN-HTPRR202B-FLK.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.