Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E52-IC35AY D=1.6 2M.
Ideal for the thermal input devices of Temperature Controllers
E52-IC35AY D=1.6 2M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnot: --.
Event inputs: -- OMRON E52-IC35AY D=1.6 2M.
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance OMRON E52-IC35AY D=1.6 2M.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions OMRON Temperature Sensor.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel OMRON Temperature Sensor. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON Temperature Sensor.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Tempeerature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E52-IC35AY D=1.6 2M.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs OMRON E52-IC35AY D=1.6 2M.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.