LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
CJ1W-V600C11 ID Sensor Unit OMRON CJ1W-V600C11 24V, 013A External, -- 
Brand: OMRON
Name: ID Sensor Unit
Model: CJ1W-V600C11
Type: CS Special I/O Unit.
Connected ID System: V680 Series; 1 Head.
External power supply: --.
No. of unit numbers used: 1 unit number.
Current consumption: 5V, 0.26A;
24V, 0.13A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC.
Allows batch transfer of data up to 32 kbytes.

Unit classification: CJ1 Special I/O Units.
Product name: Highspeed Counter Unit.
Specifications; Countable channels: 2 ,
Encoder A and B inputs, pulse input Z signals;
Open collector Input voltage: 5VDC, 12V, or 24V,
(5V and 12V are each for one axis only.) ,
Max. counting rate, 50kHz.
No OMRON CJ1W-V600C11. of unit numbers allocated: 4.
Current consumption: 5V, 0.28A; 24V, --.
Standards: UC1, N, L, CE CJ1W-V600C11
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 Counters and counts ,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 2 Digital Inputs,
2 Digital Outputs and 30 Soft Outputs OMRON CJ1W-V600C11.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables OMRON CJ1W-V600C11.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications OMRON ID Sensor Unit.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
I/O capacity/Mountable Units(Expansion Racks): 960 points/30 Units (2 Expansion Racks max OMRON ID Sensor Unit. ).
CJ1G-CPU43H Program capacity: 20K steps.
Data memory capacity: 64K words(DM: 32K words, EM: 32K words × 1 bank).
LD instructionUnit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 OMRON ID Sensor Unit.
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connecttion: Removable terminal block CJ1W-V600C11.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data OMRON CJ1W-V600C11.
Analog Output Units for converting binary ,
data into analog output signals.


...More relevant models >>>>
Last one: CJ1W-MCH71