LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
C200H-OA122-E OMRON C200H-OA122-E
Brand: OMRON
Name: Triac Output Unit
Model: C200H-OA122-E
8 pts, 1 A, 120 VAC.

Model: C200H-IA122.
No. of inputs: 16 pts.
Input voltage: 100 to 120 VAC, +10%/–15%.
Input current: 10mA, 100VAC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tioUM: 7.2K words.
DM: 6K words.
EM: -- OMRON C200H-OA122-E.
Instruction processing time (basic instructions): 0.3 µ.s min.
No. of I/O points: 880 points C200H-OA122-E
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.PC98 bus: support software.Data Setting Console Connecting Cable, For C200H-DSC01.
2MModel: C200H-MD501.
No. of I/O pts: 16 inputs, 16 outputs OMRON C200H-OA122-E.
Specifications: 5 VDC.For 1 Unit.Name: SYSMAC LINK Fiber-optic Power Supply.
Model: C200H-APS01.Model: C200H-OC221.
No. of points: 8 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Model: C200H-ID111.
No. of points: 64 pts.
Specifications: 12VDC.
Weight: 250g max.Name: Temperature Control Module.
Model: C200H-TC101.
Sensor: Platinum resistance thermometer: JPt100 Pt100 OMRON C200H-OA122-E.
Control output: Transistor output.Model: C200H-B7A22.
I/O points: 32 output points and 32 input points or 30 input points + 2 error
inputs.
Weight: 300g max.Connects Power Supply Adapter and SYSMAC NET Link Unit OMRON Triac Output Unit.
Included with C200H-APS01.Model: C200HW-BC101-V1.
No. of I/O slots: 10 slots.Model: C200H-AD001.
Input points: 4.
Voltage input: 1 to 5V or 0 to 10 V OMRON Triac Output Unit.
Current input: 4 to 20 mA.Capacity: 32K word.
Access time: 150ns.
When using SYSMAC-CPT, can not be written in EPROM.
To write a program to the EPROM, use the standard PROM writer.
Before the EPPROM memory card into the CPU, to connect the EPROM to the EPROM memory card.
If you remove the EPROM memory card from the CPU,
Will not lose its data OMRON Triac Output Unit. UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing tiime (basic instructions): 0 C200H-OA122-E. 1 µ.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-nectingg Special I/O Units: 10 OMRON C200H-OA122-E.
RS-232C: NO.Model: C200H-OC224.
No. of points: 8 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads)Independent commons.


...More relevant models >>>>