I/O points: 1024.
Processing speed: sec/ 0.15u step.
Memory capacity: 256K bytes.
Program capacity: 30K step.
Designed for applications in industrial environments.
An instruction used to perform logical operations, sequence control, timing, counting and arithmetic operations in its internal storage,
And through the digital, analog input and output, control of various types of machinery or production process.
Should be easy to make the industrial control system to form a whole, easy to expand the principle design of its functions.
Output type: transistor drain.
Output points: 32 points.
Load voltage: DC5/12.
Load current: 0.016A.
Connection: FCN connector.
Common public end points: 32.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC MITSUBISHI A2ASCPU-S30.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order
A2ASCPU-S30
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic MITSUBISHI A2ASCPU-S30.
And the control principle is decentralized, centralized and hybrid control three. Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program MITSUBISHI A2ASCPU-S30.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment MITSUBISHI CPU unit MITSUBISHI CPU unit. Type of input: DC leakage.
Input points: 64 points.
Input voltage: 12/DC24.
Input current: 2/5mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit MITSUBISHI CPU unit.
The function module is used to represent the function of the module,
Different function modules have different functions.
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and coomplex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced MITSUBISHI A2ASCPU-S30 A2ASCPU-S30.