A1S42Y MITSUBISHI A1S42Y output module
Brand: MITSUBISHI
Name: output module
Model: A1S42Y

I/O slots: 8 slots.
Could you install the power module.
Outline dimension: 420*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate MITSUBISHI A1S42Y.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board A1S42Y
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection. Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing MITSUBISHI A1S42Y.
Output points: 24 points.
Output voltage: DC24V.
OFF leakage current: 0.1mA.
Output response time: 12ms.
Output type: transistor output.
8 point /1 a public side.
With the surge absorber.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control MITSUBISHI A1S42Y.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control MITSUBISHI output module.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity MITSUBISHI output module.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc MITSUBISHI output module. .
At the same time, there is also an analog input unit (A/D),
Transform these standard electricaal signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal A1S42Y.
So the standard telecommunication number, the conversiion between the number of operations to use a variety of computing MITSUBISHI A1S42Y.
This requires the resolution of the analog unit and the standard electrical signal.