Specification: small.
Impact resistance: 120W.
Resistance to impact resistance: 35.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed.
Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 75A.
Weight: 5.7KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection. Function name: 3 phase 400V.
Power: 2.2KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage) OMRON 3G3AX-RBA1204.
Built in brake unit (brake resistance needs to be matched)
3G3AX-RBA1204
Weight: 1.9KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200% OMRON 3G3AX-RBA1204.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Frequency converter input power: 3 phase AC400V.
Weight: 2.1KG.
Standard applicable line diameter: 2 square mm or more.
Used to suppress harmonic currents generated by a transducer.
The effect of harmonic current suppression is better than that of AC reactor,
And it can be used with AC reactor OMRON 3G3AX-RBA1204. Specifications: Standard type.
Impact resistance: 300W.
Resistance to impact resistance: 50.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down OMRON Brake resistance.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed OMRON Brake resistance. Function name: 3 phase 400V.
Power: 4.0KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 2.1KG.
Dimension (w * h) 128mm *:140.
Outline dimension (deep):170 OMRON Brake resistance. 5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliiance with ISO13849-1:2008 EN (Cat 3G3AX-RBA1204. 3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Box protection class: metal, IP00.
Terminal size: M8.
Line diameter: 30 square mm.
Weight: 4.6kg.
Used to reduce the noiise from the power cord to the frequency converter or from the frequency converter to the power line OMRON 3G3AX-RBA1204.
Try to be close to the transducer for connection.