LK Automation Limited LK Automation Limited
Brand: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Go Back >> Product Catalogues
3G3AX-NFO01 Weight: 07KG OMRON 3G3AX-NFO01
Brand: OMRON
Name: Output noise filter
Model: 3G3AX-NFO01
Power supply: 3 phase 3 line rated voltage 500V AC.
Rated current: 6A.
Weight: 0.7KG.
Used to reduce the noise generated by the inverter.
Try to be close to the transducer for connection.

Function name: 3 phase 400V.
Power: 0.75KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept OMRON 3G3AX-NFO01.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication 3G3AX-NFO01
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Function name: single phase 200V.
Power: 1 OMRON 3G3AX-NFO01. 5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.6KG.
Dimension (w * h) 128mm *:108.
Outline dimension (deep):170.5mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function OMRON 3G3AX-NFO01.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specifications: Standard type OMRON Output noise filter.
Impact resistance: 200W.
Resistance to impact resistance: 180.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down OMRON Output noise filter.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed. JX / MX / RX seriesSpecification: three phase 400V.
Power: 220KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence) OMRON Output noise filter.
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 280kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high fuunctional specifications are concentrated in the compact 3G3AX-NFO01.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software. OMRON 3G3AX-NFO01.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function.


...More relevant models >>>>
Last one: 3G3AX-NFI46