Frequency converter input power: 3 phase AC400V.
Weight: 9.0KG.
Standard applicable line diameter: 60 square mm or more.
Used to suppress harmonic currents generated by a transducer.
And it can be used with AC reactor.
Function name: 3 phase 200V.
Power: 11KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 5.1KG.
Dimension (w * h) 296mm *:180.
Outline dimension (deep):175mm.
Mechanical automation concept OMRON 3G3AX-DL4220.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication
3G3AX-DL4220
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Specification: three phase 200V.
Power: 5.5KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence) OMRON 3G3AX-DL4220.
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 4kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control OMRON 3G3AX-DL4220.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function OMRON DC reactor.
Colorful function.
Brake transistor built-in.
Protection function. Cable length: 1m.
A digital operator is installed in a place far away from the transducer OMRON DC reactor. Level: 3 phase 200V level.
Connecting resistance: 17 or more.
Internal resistance value: 120W, 180W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter OMRON DC reactor. Specification: three phase 400V.
Power: 37KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 36kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high funnctional specifications are concentrated in the compact 3G3AX-DL4220.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software. OMRON 3G3AX-DL4220.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function.