Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 3.75 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication E3JK-R2M2 2M.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that
E3JK-R2M2 2M
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22 E3JK-R2M2 2M. 2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) .
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) I/O Slave Unit.
Number of words: 64Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black E3JK-R2M2 2M.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points .
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Classification: Models with built-in operation indicators.
Rated voltage: Standard products, 12, 24, 100/110, 110/120, 200/220,
orr 220/240 VAC, 12, 24, 48, or 100/110 VDC; Made-to-order items, -- OMRON E3JK-R2M2 2M.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Differeentt colors of coil tape for AC and,
DC models to more easily distinguish them OMRON E3JK-R2M2 2M.
MY(S) models with latching levers added for,
easier circuit checking.
E3JK-R2M2 2M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=E3JK-R2M2 2M&select=5