Relays with Forcibly Guided.
Contacts and High Switching.
Capacity of 10A.
Relays with forcibly guided contacts,
(EN50205 Class A, certified by VDE).
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part,
of an interlocking circuit.
Track-mounting and Back-mounting Sockets are available EE-SX676-C1J-R 0.1M Price. Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or NPN input
EE-SX676-C1J-R 0.1M
Output type: Judgement output, 2 relay contact outputs (SPST-NO) Normally energized relays (See note.);
Data transmission output, DC voltage (0 to 5 V, 1 to 5 V, 0 to 10 V) EE-SX676-C1J-R 0.1M Price.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D) .
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Right-angle/RJ45) EE-SX676-C1J-R 0.1M Price.
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks . Actuator type: Cam arm.
Operating direction: Counterclockwise operation.
Small, Lightweight Enclosed.
Switches.
V-series Switches were placed in diecast cases to provide,
superior dust resistance and mechanical strength.
Cam arms and cam roller arms can be set to any position,
within 360°. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation OMRON EE-SX676-C1J-R 0.1M.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions OMRON EE-SX676-C1J-R 0.1M. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
EE-SX676-C1J-R 0.1M Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=EE-SX676-C1J-R 0.1M&select=5